Operations Manual
Page 21
5.2 Detector Settings
Operators should be aware of other electronic equipment being used in
the immediate locality that may affect the operation of the detector.
To initialise the detector in a new area, switch the detector from Off to
Search. The detector takes 6 seconds to run through a set-up routine,
and during this time 3 long –beeps“ with a slowly rising pitch can be
heard. Once the set-up routine has completed, Noise Cancel, Audio
Reset and Ground Balance procedures should be performed as
required. Test the detector with the Test-Piece (refer Paragraph 5.4)
To restart the detector in the same operating area, switch the unit from
Off to Search. The detector will take 6 seconds to turn on, and during
this time 3 long –beeps“ with a slowly rising pitch can be heard. The
detector is now set with the same settings that were previously used,
that is, the same Audio Reset, Noise Cancel and Balance that applied
when the unit was last turned Off. Test the detector with the Test-Piece
(refer Paragraph 5.4)
Leave the detector in Search and proceed according to your
established Standing Operating Procedures for de-mining.
5.2.1 Setting the Audio Threshold
When the detector threshold gets too loud or too soft (due to extreme
temperature change or Noise Cancel resetting), conduct the following
Audio Reset control procedure:
a. Press the blue Audio Reset button.
b. The detector will emit an –eee-aww-eee“ sound when unit has been
reset. This procedure will take less than 5 seconds.
c. If all other settings have been established, test the detector with the
test piece (refer Paragraph 5.4). If the detector test is satisfactory it
is now ready for use.
CAUTION
The F1A4 cannot detect targets while the Audio Reset procedure is
being performed.
WARNING