F1A4 Field Service Manual – Level 1 and Level 2 Maintenance
Page 13
3.1.2 Servicing the Handle Camlock
3. Assembly is the reverse of the dismantling procedure, with attention to the
following:
1. Use only new components from the Handle Camlock Service Kit.
2. Ensure that the Stainless Steel Wear Plate is correctly seated in the
Handle Moulding until the Cam Lever is installed. The Cam Lever
holds the Wear Plate in place.
1. Knock out Camlock Pivot Pin
with the 3 to 3.5mm punch and
Remove the Cam Lever.
2. Remove the Stainless Steel
Wear Plate,