F1A4 Field Service Manual – Level 1 and Level 2 Maintenance
Page 32
5.3 Battery Carrier Repair Procedures
Repairs to the Battery Carrier are limited to battery terminal and wire link
replacement.
5.3.1 Battery Terminals
1. Check the Battery terminals, ensure they are not broken or loose. Replace
as required. Refer to the illustration below.
Note: When desoldering, or resoldering these terminals, do not use excessive heat
as the plastic Battery Carrier housing may be damaged.
5.3.2 Wire Links
Note: Early F1A4 Battery Carriers have 4 wire links (or round rings) and later F1A4
Battery Carriers only have 2 wire links. Both types are fully interchangeable.
1. Check the wire links connecting the battery terminal PCBs to the main PCB. If
these are the round ring type, desolder them and replace with 20mm links
made of 0.4 or 0.45mm insulated PUR (enamelled copper wire). Refer to the
illustration below: